Support relocatable reGNUal
[gnuk/neug.git] / NEWS
1 NeuG NEWS - User visible changes
2
3 * Major changes in NeuG 0.05
4
5   Released 2013-02-07, by NIIBE Yutaka
6
7 ** Improvement on SHA256 calculation
8 The output of random numbers got faster than the previous
9 implementation by 2% or so.
10
11
12 * Major changes in NeuG 0.04
13
14   Released 2012-10-30, by NIIBE Yutaka
15
16 ** Update of ChibiOS/RT
17 ChibiOS/RT is updated to newer 2.4.3.
18
19 ** Improved performance
20 Improvement on generation speed, even when it's _not_ connected to USB
21 2.0 Hub.
22
23 ** Health tests run for NEUG_MODE_RAW
24 Health tests run when NEUG_MODE_RAW (CRC32 filter output).
25
26 ** More runtime info: tool/neug_check.py 
27 Now, we can observe max counts of repeat count test, adaptive
28 propotion test 64, and adaptive propotion test 4096.
29
30
31 * Major changes in NeuG 0.03
32
33   Released 2012-10-09, by NIIBE Yutaka
34
35 ** Change RNG constuct.
36 We replace all basic components again, to conform NIST SP 800-90B.
37 Now, we use two analog inputs use in addition to Vref and Temperature
38 Sensor.  We take advantage of another A/D convertor, ADC2.
39
40 In former versions, we use LSBs of inputs.  From this version, we use
41 all bits, and put them to CRC32 calculation unit.  That's because we
42 can get more entropy when using full bits.
43
44 The central component, the conditioning component, is the one with
45 SHA-256, to conform NIST SP 80-90B.
46
47 ** New ADC (A/D convertor) driver
48 Now, we use our own ADC driver, so that we can use ADC2 and we can
49 control ADC for our particular usage (such that put it to CRC32
50 calculation unit).
51
52 ** Selection of output
53 Using "stty" command, we can now select one of three outputs: final
54 output (conditioned), CRC32 filtered raw data before conditioning, and
55 raw input data of ADC.
56
57 ** USB strings for revision detail, configure options, and system service.
58 USB strings now have more information.  There are revision detail
59 string, configure options string, system service version string, as
60 well as vendor string and product string.  These strings could be
61 examined to check NeuG device.
62
63 ** New mandatory option '--vidpid' for configure
64 You must specify USB vendor ID and product ID for Gnuk.
65 The file NEUG_USB_DEVICE_ID lists valid USB device IDs.
66
67 ** Health tests
68 Health tests are implemented to conform NIST SP 800-90B.  There are
69 three tests, repetition count test, adaptive proportion test 64,
70 and adaptive proportion test 4096.
71
72 ** System service blocks at the beginning of flash ROM.
73 Once flash ROM is protected, first 4-KiB cannot be modified.  Gnuk use
74 this area for "system service".  NeuG has compatible system service
75 block as Gnuk.  Note that this area will not be able to be modified by
76 firmware upgrade (or by any method).
77
78 ** New tool: neug_upgrade.py
79 The tool neug_upgrade.py is to send reGNUal to NeuG device.  Then, we
80 put new NeuG binary (or any binary, say, Gnuk) into the device with
81 reGNUal.
82
83 ** New tool: neug_check.py
84 The tool neug_check.py is to check the device condition.  You can see
85 error counters of NeuG device with this tool.
86
87
88 * Major changes in NeuG 0.02
89
90   Released 2012-08-30, by NIIBE Yutaka
91
92 ** Change RNG constuct.
93 We replace all basic components.  Now, we use WELL 512a structure
94 for Physical-based RNG.
95
96 ** New USB stack.
97 Now, we use our own USB stack (taken from Gnuk).
98
99
100 * Major changes in NeuG 0.01
101
102   Released 2011-11-14, by NIIBE Yutaka
103
104 ** Support more boards
105 NeuG now supports FST-01, STM8S DISCOVERY, CQ-STARM and STBee, too.
106
107 ** Change RNG construct.
108 Basic technology is basically same (CRC-16, TinyMT), but we add
109 FNV32 hash as an output function, and give a seed to TinyMT from
110 Physical-based RNG.
111
112 ** Add Test results.
113 Under test-results directory, we put results of RNG test by rng-tools,
114 NIST STS 2.1.1, and Dieharder 3.31.1.
115
116
117 * Major changes in NeuG 0.00
118
119   Released 2011-07-14, by NIIBE Yutaka
120
121 ** This is initial release.
122
123 Local Variables:
124 mode: outline
125 End: