Version 0.04
[gnuk/neug.git] / NEWS
1 NeuG NEWS - User visible changes
2
3 * Major changes in NeuG 0.04
4
5   Released 2012-10-30, by NIIBE Yutaka
6
7 ** Update of ChibiOS/RT
8 ChibiOS/RT is updated to newer 2.4.3.
9
10 ** Improved performance
11 Improvement on generation speed, even when it's _not_ connected to USB
12 2.0 Hub.
13
14 ** Health tests run for NEUG_MODE_RAW
15 Health tests run when NEUG_MODE_RAW (CRC32 filter output).
16
17 ** More runtime info: tool/neug_check.py 
18 Now, we can observe max counts of repeat count test, adaptive
19 propotion test 64, and adaptive propotion test 4096.
20
21
22 * Major changes in NeuG 0.03
23
24   Released 2012-10-09, by NIIBE Yutaka
25
26 ** Change RNG constuct.
27 We replace all basic components again, to conform NIST SP 800-90B.
28 Now, we use two analog inputs use in addition to Vref and Temperature
29 Sensor.  We take advantage of another A/D convertor, ADC2.
30
31 In former versions, we use LSBs of inputs.  From this version, we use
32 all bits, and put them to CRC32 calculation unit.  That's because we
33 can get more entropy when using full bits.
34
35 The central component, the conditioning component, is the one with
36 SHA-256, to conform NIST SP 80-90B.
37
38 ** New ADC (A/D convertor) driver
39 Now, we use our own ADC driver, so that we can use ADC2 and we can
40 control ADC for our particular usage (such that put it to CRC32
41 calculation unit).
42
43 ** Selection of output
44 Using "stty" command, we can now select one of three outputs: final
45 output (conditioned), CRC32 filtered raw data before conditioning, and
46 raw input data of ADC.
47
48 ** USB strings for revision detail, configure options, and system service.
49 USB strings now have more information.  There are revision detail
50 string, configure options string, system service version string, as
51 well as vendor string and product string.  These strings could be
52 examined to check NeuG device.
53
54 ** New mandatory option '--vidpid' for configure
55 You must specify USB vendor ID and product ID for Gnuk.
56 The file NEUG_USB_DEVICE_ID lists valid USB device IDs.
57
58 ** Health tests
59 Health tests are implemented to conform NIST SP 800-90B.  There are
60 three tests, repetition count test, adaptive proportion test 64,
61 and adaptive proportion test 4096.
62
63 ** System service blocks at the beginning of flash ROM.
64 Once flash ROM is protected, first 4-KiB cannot be modified.  Gnuk use
65 this area for "system service".  NeuG has compatible system service
66 block as Gnuk.  Note that this area will not be able to be modified by
67 firmware upgrade (or by any method).
68
69 ** New tool: neug_upgrade.py
70 The tool neug_upgrade.py is to send reGNUal to NeuG device.  Then, we
71 put new NeuG binary (or any binary, say, Gnuk) into the device with
72 reGNUal.
73
74 ** New tool: neug_check.py
75 The tool neug_check.py is to check the device condition.  You can see
76 error counters of NeuG device with this tool.
77
78
79 * Major changes in NeuG 0.02
80
81   Released 2012-08-30, by NIIBE Yutaka
82
83 ** Change RNG constuct.
84 We replace all basic components.  Now, we use WELL 512a structure
85 for Physical-based RNG.
86
87 ** New USB stack.
88 Now, we use our own USB stack (taken from Gnuk).
89
90
91 * Major changes in NeuG 0.01
92
93   Released 2011-11-14, by NIIBE Yutaka
94
95 ** Support more boards
96 NeuG now supports FST-01, STM8S DISCOVERY, CQ-STARM and STBee, too.
97
98 ** Change RNG construct.
99 Basic technology is basically same (CRC-16, TinyMT), but we add
100 FNV32 hash as an output function, and give a seed to TinyMT from
101 Physical-based RNG.
102
103 ** Add Test results.
104 Under test-results directory, we put results of RNG test by rng-tools,
105 NIST STS 2.1.1, and Dieharder 3.31.1.
106
107
108 * Major changes in NeuG 0.00
109
110   Released 2011-07-14, by NIIBE Yutaka
111
112 ** This is initial release.
113
114 Local Variables: